Salta al contenuto principale
Home

Dedicated to discovery

  • A proposito di ELGA
    • A proposito di ELGA
    • Carriere
    • Eventi
  • Supporto
    • Laboratory Planning
  • Contatti
  • EN
  • DE
  • ES
  • FR
  • PT
  • EN-US
Home
  • Prodotti
    • PURELAB
      • PURELAB® Dispenser
      • PURELAB® Flex
      • PURELAB® Quest
      • PURELAB® Pharma Compliance
      • PURELAB® Chorus 1 Complete
      • PURELAB® Chorus 1
      • PURELAB® Chorus 2
      • PURELAB® Chorus 3
      • PURELAB® Chorus 2 +
    • CENTRA
      • CENTRA® R60/120
      • CENTRA® R200
      • CENTRA® RDS
    • MEDICA
      • MEDICA® 150
      • MEDICA® 7/15
      • MEDICA® BIOX 2024
      • MEDICA® Pro-R & Pro-RE
      • MEDICA® R200
      • MEDICA® EDI 15/30
      • MEDICA® Pro-LPS
      • MEDICA® Pro EDI 60/120
      • MEDICA® BIOX
      • Hubgrade
    • BIOPURE
      • BIOPURE® 300/600
    • PURENERGY® 30
    • ELGA Gamma Completa di Prodotti
  • Applicazioni
    • Analisi microbiologica
    • Biochimica clinica
    • Colture cellulari
    • Cromatografia liquida
      • High Performance Liquid Chromatography
    • Elettrochimica
    • Gascromatografia
    • Genetica
    • High Performance Liquid Chromatography (HPLC)
    • Immunochimica
    • Requisiti dell'acqua per laboratori generici
    • Spettrofotometria
    • Spettrometria di massa
    • Spettroscopia atomica
  • Tecnologie
    • Activated Carbon
    • Electrodeionization (EDI)
    • Filtration
    • Ion Exchange
    • PureSure
    • Reverse Osmosis
    • Ultraviolet
  • Impurità nell'acqua
    • Dissolved Gases
    • Inorganic Compounds
    • Microorganisms & Bacteria
    • Organic Compounds
    • Particulates
  • Conoscenza
    • BROSCHÜREN
    • Blog
    • Casi di studio
    • Acqua ultrapura
    • Guide e libri bianchi
  • Where to buy
  • Contattaci
Home
  • Contattaci
  • Prodotti
    • PURELAB
      • PURELAB® Dispenser
      • PURELAB® Flex
      • PURELAB® Quest
      • PURELAB® Pharma Compliance
      • PURELAB® Chorus 1 Complete
      • PURELAB® Chorus 1
      • PURELAB® Chorus 2
      • PURELAB® Chorus 3
      • PURELAB® Chorus 2 +
    • CENTRA
      • CENTRA® R60/120
      • CENTRA® R200
      • CENTRA® RDS
    • MEDICA
      • MEDICA® 150
      • MEDICA® 7/15
      • MEDICA® BIOX 2024
      • MEDICA® Pro-R & Pro-RE
      • MEDICA® R200
      • MEDICA® EDI 15/30
      • MEDICA® Pro-LPS
      • MEDICA® Pro EDI 60/120
      • MEDICA® BIOX
      • Hubgrade
    • BIOPURE
      • BIOPURE® 300/600
    • PURENERGY® 30
    • ELGA Gamma Completa di Prodotti
  • Applicazioni
    • Analisi microbiologica
    • Biochimica clinica
    • Colture cellulari
    • Cromatografia liquida
      • High Performance Liquid Chromatography
    • Elettrochimica
    • Gascromatografia
    • Genetica
    • High Performance Liquid Chromatography (HPLC)
    • Immunochimica
    • Requisiti dell'acqua per laboratori generici
    • Spettrofotometria
    • Spettrometria di massa
    • Spettroscopia atomica
  • Tecnologie
    • Activated Carbon
    • Electrodeionization (EDI)
    • Filtration
    • Ion Exchange
    • PureSure
    • Reverse Osmosis
    • Ultraviolet
  • Impurità nell'acqua
    • Dissolved Gases
    • Inorganic Compounds
    • Microorganisms & Bacteria
    • Organic Compounds
    • Particulates
  • Conoscenza
    • BROSCHÜREN
    • Blog
    • Casi di studio
    • Acqua ultrapura
    • Guide e libri bianchi
  • Where to buy
  • Contattaci
  • A proposito di ELGA
    • A proposito di ELGA
    • Carriere
    • Eventi
  • Supporto
    • Laboratory Planning
  • Contatti
  • EN
  • DE
  • ES
  • FR
  • PT
  • EN-US
  • Normativa sulla privacy
  • Termini e condizioni
  • Dichiarazioni di conformità legale globale
  • Brevetti
  • Trademarks
  • Impressum
  • A new photothermal device for seawater desalination
Water Purity

A new photothermal device for seawater desalination

18 Lug 2022
- by ELGA Editorial Team

A new photothermal device for seawater desalinationThe number of countries suffering from shortages of fresh drinking water has risen significantly in recent years due to rapid population growth, climate change and the intensification of industries such as agriculture. Since seawater represents about 96.7 % of the total available water on the earth, desalination by seawater reverse osmosis (SWRO) is currently the most economical way to produce potable water. However, SWRO only demonstrates around 50% efficiency, due to technical limitations related to high osmotic pressures and the concentration polarisation phenomenon. This led a team of scientists from the United Arab Emirates (UAE) and Italy to evaluate a plasmonic photothermal membrane distillation tool that could drastically increase the efficacy of seawater desalination.

Membrane distillation (MD) has emerged as a potential alternative or complementary technique to SWRO in recent years. However, conventional MD systems are negatively affected by temperature polarisation, which drastically reduces their performance.

One option for increasing desalination capacity could be photothermal membrane distillation (PMD), a hybrid thermal membrane technology based on the use of microporous hydrophobic membranes. The plasmonic photothermal MD device comprises advanced nanostructured membranes with metallic nanoparticles (NPs) in polymeric matrixes. This novel method is unlimited by osmotic phenomena, and so it can produce desalted water with a high thermal efficiency of over 85 % and a comparatively low energy input. Researchers from the Masdar Institute of Science and Technology in the UAE, and the National Research Council of Italy (ITM-CNR) and the Italian universities of Calabria and Sassari, have studied the effects of NP content on the membrane surface temperature resulting from the polarisation phenomenon, to determine the influence of photothermal plasmonic excitation on MD function.1  

 

Sample preparation and analysis

Deionised water produced by a PURELAB® water purification system from ELGA LabWater was used throughout the investigation. Silver (Ag) NPs were synthesised by chemical reduction with sodium citrate as a metal precursor, and flat-sheet microporous membranes containing Ag NPs were prepared by the nonsolvent-induced phase inversion process. Scanning electron microscopy

and transmission electron microscopy were carried out to establish the influence of the Ag NPs on the surface and cross-sectional morphology of the membranes. To explore the photothermal effects on the membrane, a high-pressure UV mercury lamp was used to irradiate a dedicated dead-end vacuum MD cell while a feed solution was pumped over the membrane. The membrane surface temperature was monitored with a probe during the experiment. A comparative energy analysis between the vacuum MD prototype and a standard reverse osmosis set-up was also performed.

 

Results

The photothermal heat flux was 1.7 times greater for tests with pure water than the latent heat flux associated with the water evaporation through the membrane, and was approximately doubled for a saline solution. The thermal radiation energy of the UV lamp raised the surface temperature by about 2.5 K in membranes without Ag NPs, compared to an increase of 4 K in those containing these metallic nanoparticles.

This study demonstrated that thermoplasmonic effects were promoted by photothermal excitations of Ag NPs incorporated into microporous membranes. This raised the feed temperature at the membrane surface exposed to UV irradiation, and so reversed temperature polarisation, achieving a previously unrecorded MD efficiency. 

 

Future applications

Despite the promising early results, the major challenge facing this new MD equipment, is the scale-up from a micrometre to an industrial scale. Energy consumption is a key factor to consider in scaling up, and the comparative energy analysis shows that this novel thermoplasmonic technique has the potential to reduce energy demands by 25%, significantly boosting the performance of the pre-existing MD system. The ability of PMD to effectively operate at high salt concentration, regardless of osmotic counter pressures, could play a vital role in enhancing water quality and desalting capacity, ultimately improving the sustainability and productivity of the seawater desalination process.

 

Why Choose ELGA LabWater?

The presence of impurities in laboratory water can be a major problem in research experiments, and can seriously compromise results. ELGA LabWater has been a trusted supplier or pure and ultrapure water since 1937. We believe in giving you choice in how you use our water purification solutions, supported by excellent service and support. For more information on our Type I ultra pure water systems, check out our PURELAB Quest, PURELAB Chorus 1 Complete and our PURELAB flex models.

 

References

1 Politano, A et al. 2017. Photothermal Membrane Distillation for Seawater Desalination. Advanced Materials 29:10.1002/adma.201603504.

  • Sales Enquiry
  • Richiedi un Preventivo
  • Technical Support
  • Trova un Partner Approvato

Sales Enquiry

At ELGA LabWater, we have exciting offers and news about our products and services that we hope you’d like to hear about. We will use your information to predict what you might be interested in. We will treat your data with respect and you can find the details in our Privacy Policy.

ELGA LabWater works with a network of Approved Partners. In order to answer your questions or enquiries, we may pass your contact details to an Approved Partner, who may contact you directly. 

I'd like to receive updates from ELGA LabWater & ELGA Approved Partners based on my details.

Richiedi un Preventivo

At ELGA LabWater, we have exciting offers and news about our products and services that we hope you’d like to hear about. We will use your information to predict what you might be interested in. We will treat your data with respect and you can find the details in our Privacy Policy.

ELGA LabWater works with a network of Approved Partners. In order to answer your questions or enquiries, we may pass your contact details to an Approved Partner, who may contact you directly. 

I'd like to receive updates from ELGA LabWater & ELGA Approved Partners based on my details.

Technical Support

At ELGA LabWater, we have exciting offers and news about our products and services that we hope you’d like to hear about. We will use your information to predict what you might be interested in. We will treat your data with respect and you can find the details in our Privacy Policy.

ELGA LabWater works with a network of Approved Partners. In order to answer your questions or enquiries, we may pass your contact details to an Approved Partner, who may contact you directly. 

Call us

Can't find what you are looking for?

Support Number
+44 (0)20 3567 7300
United Kingdom Sales
+44 (0)1628 879 704
United States of America Sales
+1 877-315-3542
France Sales
+33 1 40 83 65 00
China Sales
+86 400-616-8882

 

ELGA LabWater Sede Centrale

Lane End Business Park
Lane End, High Wycombe
HP14 3BY
United Kingdom
T: +44 (0) 203 567 7300
F: +44 (0) 203 567 7205

Casi di Studio

  • Abbott Diagnostics
  • DASA Diagnostica Medica
  • NeoDIN Istituto Medico
  • North Staffordshire NHS Trust
  • Scuola Professionale Olsberg

Risorse

  • Informazioni sull'acqua ultrapura
  • Guide e libri bianchi
  • Tecnologie per la purificazione dell'acqua
  • Applicazioni di laboratorio
  • Impurità nell'acqua
  • Latest Blog
  • Water Purity - Different Types of Pure Water
  • What is Clinical Laboratory Reagent Water (CLSI)?
  • What is Total Organic Carbon (TOC)?

© VWS (UK) Ltd. che opera come ELGA LabWater. 2025 - Tutti i diritti riservati.
ELGA è il marchio mondiale dell'acqua di laboratorio di Veolia.

  • Normativa sulla privacy
  • Termini e condizioni
  • Dichiarazioni di conformità legale globale
  • Brevetti
  • Trademarks
  • Impressum
  • Lingua
    • Deutsch
    • English
    • Español
    • Français
    • Italiano
    • Português
    • 日本語
    • 中文
  • Altri Siti Veolia
    • Veolia
    • Veolia Foundation
    • Veolia Water Technologies
Elga Veolia
TOP

© 2017 ELGA Veolia